Sorption-spectroscopic determination of palladium in spent automobile catalysts using poly(N-vinylimidazole) cross-linked with epichlorohydrin
DOI:
https://doi.org/10.17308/sorpchrom.2026.26/14348Keywords:
sorption, palladium, spent automotive catalysts, poly(N‑vinylimidazole), spectrophotometry, separation and concentrationAbstract
The sorption of palladium(II) and gold(III) by a sorbent based on poly(N‑vinylimidazole) cross‑linked with epichlorohydrin from hydrochloric acid solutions with a pH of 2.0, in the presence of a 10‑fold excess of copper(II), nickel(II), cobalt(II), zinc(II) and cadmium(II), was studied under dynamic conditions. The study was carried out by passing the sorption solution through a concentrating cartridge with a sorbent mass of 0.1000 g, with an initial concentration of palladium(II) and gold(III) of 1∙10⁻⁴ mol/dm³. The content of metal ions in the solutions was determined by atomic absorption spectroscopy. As a result of the studies, it was established that poly(N‑vinylimidazole) selectively extracts ions of noble metals in the presence of a number of non‑noble metals. It has been established that using 10.0 cm³ of a 1% thiourea solution in 0.1 mol/dm³ HCl allows for quantitative desorption of palladium(II) from poly(N‑vinylimidazole). A method has been developed for the spectrophotometric determination of palladium in spent automotive catalyst (SAC) using preliminary concentration on poly(N‑vinylimidazole) cross‑linked with epichlorohydrin. Based on the data obtained, the mass fraction of palladium in the spent automotive catalyst was determined..