Sorption of flavonoids from aqueous acetonitrile solutions containing imidazolium ionic liquids on octadecyl silica gel under RP-HPLC condi-tions
Abstract
Flavonoids are biologically active compounds in medicinal plants, they are widely used in the production of herbal medicines. In this regard, it is important to study the relationship between the structure of sorbates and their retention and to understand the influence of various additives on the chromatographic analysis for their qualitative and quantitative determination by reversed-phase HPLC (RP HPLC). In this paper, we studied the influence of the structure of some flavonoids on their retention in the aqueous acetonitrile solution/imidazolium ionic liquid (IL)/octadecyl silica gel systems. It was shown that the planarity of flavonoids is one of the main factors influencing the retention. It was found that planar molecules of flavonoid aglycones are retained on octadecyl silica gel in aqueous acetonitrile systems containing ILs much better than flavonoid glycosides. It was determined that the nature and structure of the IL used as a specific additive to the aqueous acetonitrile eluent significantly change the retention factors of the studied flavonoids. In particular, it was found that retention factors of flavonoids increase in systems with bromide ILs in the following series: [C4dMIM][Br]<[C4MIM][Br]<[C6MIM][Br]<[C10MIM][Br]. The retention of flavonoids in systems with imidazolium bromide ILs is greater than in systems with similar tetrafluoroborate ILs: ([C6MIM][BF4]<[C6MIM][Br] and [C10MIM][BF4]<[C10MIM][Br]). ILs containing an additional methyl group in the 2-position of the imidazole ring show the opposite trend: the retention factor with bromide ILs is lower than with tetrafluoroborate ILs ([C4dMIM][BF4]>[C4dMIM][Br]). Changes in the retention factors in systems with different ILs are associated with changes in the hydrophobic effect in the system due to the different impacts of the cosmotropic and chaotropic effects of IL cations and anions on the aqueous acetonitrile solution. We analysed the concentration dependences of retention factors using the Snyder-Sochevinsky and Sochevinsky-Wachtmeister models (the range of acetonitrile content was 20÷40 vol.%). We obtained the corresponding linear equations with high values of the determination coefficients, which were used to find the angular coefficients within the considered models.
Downloads
References
Tungmunnithum D., Thongboonyou A., Pholboon A., Yangsabai A. Flavonoids and other phenolic compounds from medicinal plants for pharmaceutical and medical aspects: An overview, Medicines. 2018; 5(3): 93. https://doi.org/10.3390/medicines5030093
Mutha R.E., Tatiya A.U., Surana S.J. Flavonoids as natural phenolic compounds and their role in therapeutics: An overview, Future journal of pharmaceutical sciences. 2021; 7: 1-13. https://doi.org/10.1186/s43094-020-00161-8
Mizzi L., Chatzitzika C., Gatt R., Valdramidis V. HPLC analysis of phenolic compounds and flavonoids with overlapping peaks, Food technology and biotechnology. 2020; 58(1): 12-19. https://doi.org/10.17113/ftb.58.01.20.6395
Deineka V.I., Oleinits E.Y., Blinova I.P., Deineka, L.A. Selectivity Control of the Separation of Anthocyanins: Replacing Acetonitrile for Methanol in the Mobile Phase, J. Anal. Chem. 2021; 76: 939-945. https://doi.org/10.1134/S1061934821060022
Li S., Tian M., Row K. H. Effect of mobile phase additives on the resolution of four bioactive compounds by RP-HPLC, Int. J. Mol. Sci. 2010; 11(5): 2229-2240. https://doi.org/10.3390/ijms11052229
Qiu H., Mallik A.K., Takafuji M., Jiang S., Ihara H. Ionic liquids in liquid chromatography. Handbook of ionic liquids: properties, applications and hazards. 2012. 325-350.
Ho T.D., Zhang C., Hantao L.W., Anderson J.L. Ionic liquids in analytical chemistry: fundamentals, advances, and perspectives, Anal. Chem. 2014; 86(1): 262-285. https://doi.org/10.1021/ac4035554
David V., Moldoveanu S.C. Ionic Liquids in Liquid Chromatography, In Analytical Liquid Chromatography-New Perspectives. 2022; 1-16. http://dx.doi.org/10.5772/intechopen.104122
Fan Z., Yu H. Determination of piperidinium cations by hydrophilic interaction chromatography with imidazolium ionic liquids as mobile phase additives, J. Anal. Chem. 2019; 74: 126-133. https://doi.org/10.1134/S1061934819020059
He L., Zhang W., Zhao L., Liu X., Jiang S. Effect of 1-alkyl-3-methylimidazolium-based ionic liquids as the eluent on the separation of ephedrines by liquid chromatography, J. Chromatogr. A. 2003; 1007(1-2): 39-45. https://doi.org/10.1016/S0021-9673(03)00987-7
Axente R.E., Stan M., Chitescu C.L., Nitescu V.G., Vlasceanu A.M., Baconi D.L. Application of Ionic Liquids as Mobile Phase Additives for Simultaneous Analysis of Nicotine and Its Metabolite Cotinine in Human Plasma by HPLC–DAD, Molecules. 2023; 28(4): 1563. https://doi.org/10.3390/molecules28041563
Petruczynik A. Effect of ionic liquid additives to mobile phase on separation and system efficiency for HPLC of selected alkaloids on different stationary phases, Journal of chromatographic science. 2012; 50(4): 287-293. https://doi.org/10.1093/chromsci/bms004
Yashin Y.I., Yashin A.Y. Sorbents for HPLC. Current state and new directions of development (Overview), Sorbtsionnye I Khromatograficheskie Protsessy. 2021; 21(2): 235-245. https://doi.org/10.17308/sorpchrom.2021.21/3357 (In Russ.)
Carda-Broch S., García-Alvarez-Coque M.C., Ruiz-Angel M.J. Extent of the influence of phosphate buffer and ionic liquids on the reduction of the silanol effect in a C18 stationary phase, J. Chromatogr. A. 2018; 1559: 112-117. https://doi.org/10.1016/j.chroma.2017.05.061
Trujillo-Rodríguez M.J., Nan H., Varona M., Emaus M.N., Souza I.D., Anderson J.L. Advances of ionic liquids in analytical chemistry, Anal. Chem. 2018; 91(1): 505-531. https://doi.org/10.1021/acs.analchem.8b04710
Somova V.D., Bessonova E.A., Kartsova L.A. A new version of hydrophilic interaction liquid chromatography with the use of ionic liquids based on imidazole for the determination of highly polar drugs in body fluids, Analitika i kontrol’ [Analytics and Control]. 2017; 21(3): 241-250. http://dx.doi.org/10.15826/analitika.2017.21.3.004 (In Russ.)
Peris-García E., Burgos-Gil R., García-Alvarez-Coque M.C., Ruiz-Angel M.J. Hydrophilic liquid chromatography versus reversed-phase liquid chromatography in the absence and the presence of 1-hexyl-3-methylimidazolium chloride for the analysis of basic compounds, Separations. 2020; 7(2): 30. https://doi.org/10.3390/separations7020030
Zhang Y.N., Yu H., Ma Y.J., Cui G. Imidazolium ionic liquids as mobile phase additives in reversed phase liquid chromatography for the determination of iodide and iodate, Anal. Bioanal. Chem. 2018; 410: 7347-7355. https://doi.org/10.1007/s00216-018-1347-5
Zhang Y.N., Yu H. Imidozolium ionic liquids as mobile phase additives in reversed phase liquid chromatography for the analysis of anions, Chromatographia, 2017; 80: 1615-1622. https://doi.org/10.1007/s10337-017-3409-9
Raznitsyna V.M., Shafigulin R.V., Vinogradov K.Yu., Bulanova A.V. Influence of the structure of imidazolium ionic liquids on the chromatographic behaviour of some flavonoids under RP HPLC conditions, Sorbtsionnye i khromatograficheskie protsessy. 2023; 23(4): 592-605. https://doi.org/10.17308/sorpchrom.2023.23/11568 (In Russ.)
Komsta Ł.A new general equation for retention modeling from the organic modifier content of the mobile phase, Acta Chromatographica. 2010; 22(2): 267-279. https://doi.org/10.1556/achrom.22.2010.2.9
Soczewinski E. Solvent composition effects in thin-layer chromatography systems of the type silica gel-electron donor solvent, Anal. Chem. 1969; 41(1): 179-182. https://doi.org/10.1021/ac60270a035
Soczewiński E. Mechanistic molecular model of liquid–solid chromatography: Retention–eluent composition relationships, J. Chromatogr. A. 2002; 965(1-2): 109-116. https://doi.org/10.1016/S0021-9673(01)01278-X
Pitucha M., Matysiak J., Senczyna B. Synthesis and RP HPLC studies of biologically active semicarbazides and their cyclic analogues 1, 2, 4-triazol-3-ones, Monatshefte für Chemie-Chemical Monthly. 2012. 143: 657-667. https://doi.org/10.1007/s00706-011-0715-z
Soczewiński E., Wachtmeister C.A. The relation between the composition of certain ternary two-phase solvent systems and RM values, J. Chromatogr. A. 1962. 7: 311-320. https://doi.org/10.1016/S0021-9673(01)86422-0
Snyder L.R., Dolan J.W., Gant J.R. Gradient elution in high-performance liquid chromatography: I. Theoretical basis for reversed-phase systems, J. Chromatogr. A. 1979. 165(1): 3-30. https://doi.org/10.1016/S0021-9673(00)85726-X
Civadze A.Ju. Ctrukturnaja samoorganizacija v rastvorah i na granice razdela faz. Moskva, LKI, 2008, 544 p
Deineka V.I., Deineka L.A., Saenko I.I., Chulkov A.N. A float mechanism of retention in reversed-phase chromatography, Russian Journal of Physical Chemistry A. 2015. 89: 1300-1304. https://doi.org/10.1134/S0036024415070079
García-Alvarez-Coque M.C., Ruiz-Angel M.J., Berthod A., Carda-Broch S. On the use of ionic liquids as mobile phase additives in high-performance liquid chromatography. A review, Anal. Chim. Acta. 2015; 883: 1-21. https://doi.org/10.1016/j.aca.2015.03.042
Buszewska-Forajta M., Markuszewski M.J., Kaliszan R. Free silanols and ionic liquids as their suppressors in liquid chromatography, J. Chromatogr. A. 2015; 1559: 17-43. https://doi.org/10.1016/j.chroma.2018.04.002
Marszałł M.P., Bączek T., Kaliszan R. Reduction of silanophilic interactions in liquid chromatography with the use of ionic liquids, Anal. Chim. Acta. 2005; 547(2): 172-178. https://doi.org/10.1016/j.aca.2005.05.045
Lisichkin G.V. Khimija Privitykh Poverhnostnykh Soedinenij. M., Fizmatlit, 2003, 592 p.
Zhao H. Are ionic liquids kosmotropic or chaotropic? An evaluation of available thermodynamic parameters for quantifying the ion kosmotropicity of ionic liquids. Journal of Chemical Technology & Biotechnology: International Research in Process, Environmental & Clean Technology 2006; 81(6): 877-891. https://doi.org/10.1002/jctb.1449