Influence of eluent composition on retention by hypercrosslinked polystyrene in RP HPLC

  • Sergei V. Prokopov post-graduate (student), department of Physical Chemistry and Chromatography, Samara State University, Samara
  • Irina V. Frolova magistrand of Physical Chemistry, Chemical Faculty, Samara State University, Samara
  • Svetlana V. Kurbatova Doctor of Chemistry Science, professor, dean of Chemical Faculty, Samara State University, Samara, e-mail: curbatsv@ssu.samara.ru
Keywords: reversed-phase high performance liquid chromatography, hypercrosslinked polystyrene, octadecylsilicagel, mobile phase composition.

Abstract

Chromatographic retention of some organic compounds was investigated under different eluent
composition within the limits of Snyder, Snyder – Sochevinsky and Scott – Cućera models on the
octadecylsilicagel and hypercrosslinked polystyrene. Application limites of such models were estimated,
retention mechanism of investigated substances on both sorbents were compared.

Downloads

Download data is not yet available.

References

1.Шатц В.Д., Сахартова О.В. Высокоэффективная жидкостная хроматография.
Рига: Зинатне, 1988. 390 с.
2.Snyder L.R., Dolan J.W., Gant J.R. Gradient elution in high-performance liquid
chromatography. I. Theoretical basis for reversed-phase systems // J. Chromatogr. 1979.
V. 165 P 3.
3.Soczewinski E. Solvent composition effects in TLC systems of the type silica gelelectron
donor solvuit. // Anal. Chem. 1969. V. 41. P. 179.
4.Scott R.P.W., Kucera P. Examination of five commercially available liquid
chromatographic reversed phases (including the nature of the solute-solvent-stationary
phase interactions associated with them) // J. Chromatogr. 1977. V. 142. P. 213.
5.Ланин С.Н., Ланина Н.А., Никитин Ю.С. Влияние ассоциации молекул сорбата и
модификатор в подвижной фазе на удерживание в высокоэффективной жидкостной
хроматографии // Журн. физ. химии. 1995. Т. 69. № 11. С. 2045.
6.Davankov V., Tsyurupa M., Ilyin M., Pavlova L. Hypercross-linked polystyrene and its
potentials for liquid chromatography: a mini-review // J. Chromatogr. A. 2002. V. 965.
P. 65.
7.Davankov V.A., Sychov C.S., Ilyin M.M., Sochilina K.O. Hypercrosslinked
polystyrene as a novel type of high-performanceliquid chromatography column packing
material. Mechanisms of retention // J. Chromatogr. A. 2003. V. 987. P. 67.
8.Tate P.A., Dorsey J.G. Column selection for liquid chromatographic estimation of the
k’w hydrophobicity parameter. // J. Chromatogr. A. 2004. V. 1024. P. 37.
9.Ланин С.Н. Адсорбционные модели удерживания в жидкостной хроматографии /
100 лет хроматографии. М.: Наука, 2003. С. 407.
10. Penner N.A., Nesterenko R.N., Ilyin M.M., Tsyurupa M.P., Davankov V.A.
Investigation of the Properties of Hypercrosslinked Polystyrene as a Stationary Phase for
High-Performance Liquid Chromatography // Chromatographia 1999. Vol. 50. № 9/10. P.611.
11. Sychov C.S., Ilyin M.M., Davankov V.A., Sochilina K.O. Elucidation of retention
mechanisms on hypercrosslinked polystyrene used as column packing material for highperformance
liquid chromatography // J. Chromatogr. A. 2004. V. 1030. P. 17.
Published
2019-11-22
How to Cite
Prokopov, S. V., Frolova, I. V., & Kurbatova, S. V. (2019). Influence of eluent composition on retention by hypercrosslinked polystyrene in RP HPLC. Sorbtsionnye I Khromatograficheskie Protsessy, 12(3). Retrieved from https://journals.vsu.ru/sorpchrom/article/view/1791